Torque Transducers, Torque Sensors and other torque measurement solutions

Type 135 RS485 Load Cell Amplifier

 
Type135 RS485 Load Cell Amplifier
The Type 135 RS485 Amplifier is ideal for applications requiring a number of distributed strain measurements from any full bridge strain sensors (load cell, pressure transducers, strain gauges, Bolt-on etc).

Up to 50 Load Cells can be configured within one network solution and controlled via your PC or laptop.

The Type 135 is designed for use with either customer’s software or the Datum Net Display Software; the transmission protocol is available for developers wishing to configure their own software interface.




NetDisp Software

The Datum Electronics NetDisp software is a Windows™ PC based software package, designed to gather data from up to a total number of 50 Load Cells, connected to an RS485 Network via Datum Electronics Type135 , RS485 Network Strain Gauge Amplifiers.

Each Load Cell on the Network is individually calibrated to give an output in Kg.

The software package sequentially reads the current load value from each cell and processes all load values to provide Display and Group Sum functions.

The software allows for the load value of groups of cells to be summed together to give a total load for the group. This Total Load is treated in the same way as Individual Cell Load for display & alarm functions.

A “Standard NetDisp” system includes up to 16 visual on screen alarms and would comprise the following components:

  • NetDisplay Interface Module
  • Includes regulated power supply for the networked amplifiers
  • “NetDisplay” software Disk and “End User license”
  • Choice of RS485 or USB interfaces into the PC

 


Enclosure

Type 135 RS485 EnclosureHoused within a Die Cast Aluminium enclosure, this robust amplifier is ideal for applications requiring a number of distributed strain sensors logged into a single PC with interface software.

 

  

 








Data Sheet

Type 135 RS485 Load Cell Amplifier

 
 
Product PDFData Sheet (Adobe Reader required)

Specifications

  • 8-24V Supply Voltage
  • Up to 63 Nodes
  • Up to 16 Bit resolution
  • +/-3mV/V input Range available
  • 128SPS @ 12 Bit (8 SPS @ 16 Bit)
  • Self contained unit with Power and Data LED indication or PCB
  • Baud rate configurable from 4800 to 57,600